Download brochure

DNG Dispensers

CNG
CNG CNG CNG

Dispensers of the DNG series are intended to public or private stations for the refueling of light or heavy vehicles using compressed natural gas (CNG).

DNG Dispensers are managed by an electronic computer of the last generation and combined with backlit LCD or high efficiency red LED display. Dispensers are manufactured and tested according to current European standards and to ATEX and CE regulations. On request the dispenser can be made following different standards according to different market requirements and features.

Below is an example of the composition of the code to indicate the type of provider and the various main options.

Service type Car or Bus vehicle
Gas type Natural gas density 0,65…….0,87 Kg/m3
Working temperature -25…….55°c (other on request)
Nominal pressure 220 bar
Max pressure 250 bar
Accuracy Better of ± 0,5%
Power supply 230 Vac +/- 15% 50-60Hz
Instrument air Dry air 6….12 bar
Nominal flow rate 25 Kg/min
Max flow rate 60 kg/min